Management of Common Issues Related to Permeation Water in Newly Built Residential Communities (Part 2)
Release time:
2019-09-20
Source:
2. Analysis of the causes of water seepage in balconies and terraces and treatment plans
2.1 Accident characteristics
Water seepage on the concrete surface of balconies and terraces.
2.2 Cause analysis
(1) The concrete vibration of the balcony and terrace structural beams and slabs is not solid.
(2) The waterproof layer of JS coating is not constructed according to the specifications.
(3) The large area balcony and terrace expansion joints are not filled tightly with waterproof materials.
2.3 Treatment methods
(1) Use two-component polyurethane sealant to fill the expansion joints.
(2) Use water-soluble polyurethane grouting liquid for chemical grouting at the leaking areas, ensuring sufficient grouting until the original slurry emerges.
2.4 Preventive measures
(1) Strengthen the quality control of concrete pouring for structural beams and slabs to ensure the entire structure is compact.
(2) Directly apply Meihui JS one cloth and five coatings on the surface of the structural slab, with a 200mm high upward turn on all sides.
(3) Remove debris from the expansion joints and use two-component polyurethane sealant for sealing, ensuring tight filling.
2.5 Quality control
Strengthen the quality control of concrete pouring, and the JS waterproof layer must be directly applied to the structural surface.
RELATED INFORMATION
FUJIAN HUIXING COATINGS TECHNOLOGY DEVELOPMENT CO., LTD
TEL /400-995-8827
Address: Quanhui Petrochemical Park, Fujian Province
Website: www.fjhuixing.cn
Subscribe to us
Enter your email address to register for new service notifications.
Page Copyright © 2024 Fujian Huixing Coating Technology Development Co., Ltd.