Management of Common Issues Related to Permeation Water in Newly Built Residential Communities (Part Six)
Release time:
2019-09-20
Source:
6. Analysis of the causes of water seepage at the corners of the roof with different heights and the base of the chimney, and treatment plan
6.1 Accident Characteristics
The waterproof layer construction at the corners of the roof with different heights and the base of the chimney is not standardized, and the concrete has cracked, allowing rainwater to enter the interior through the gaps.
6.2 Cause Analysis
(1) The fillet at the connection between the high and low roof and the chimney was not rounded as required, and the waterproof layer was set unreasonably.
(2) The waterproof layer was not turned up as required, or the waterproof layer was set on the plastering; when the plaster layer cracked, rainwater entered the interior through the cracks.
(3) The height of the chimney wind cap's wind deflector is too high (180mm), allowing rainwater to directly enter the interior from the flue when encountering oblique wind and rain.
6.3 Treatment Methods
(1) Cut the plaster layer of the high wall surface by 20-50mm.
(2) Embed the end of the "JS" waterproof coating into the seam, and then use polymer waterproof mortar for plastering, forming a radius of 50mm at the corners.
6.4 Preventive Measures
(1) At the intersection of the high and low roofs, set a 250mm high plain concrete upturned beam, and pour it together with the low span structural roof concrete.
(2) Directly apply Meihui waterproof coating with one layer of fabric and five coats on the surface of the structural slab, with an upturned height of no less than 250mm.
(3) At the corners of the roof with different heights, gable walls, and the base of the chimney, use polymer waterproof mortar to form a radius of 50mm at the corners, with specific methods detailed in (Figure 5).
(4) Lower the height of the chimney wind cap's wind deflector to 120mm.
6.5 Quality Control
The plain concrete upturned beam must be poured together with the low span structural roof.
RELATED INFORMATION