Detailed introduction
Basic layer requirements:
The base should be flat, without dead bends, sharp edges, solid, and clean. Cracks, looseness, sand rising, hollow sounds, and uneven areas need to be treated in advance; corners and angles should be rounded (radius 50mm); it does not need to be dry or have visible water; if too dry, it should be moistened with water.
Construction method:
1. Pour into the mixing bucket, use an electric mixer to stir, and slowly add the matching powder components while stirring. After fully mixing, set aside. Material mixing: according to the mixing ratio indicated on the product packaging label, first add the liquid material components.
2. Coating can be done using rolling, brushing, or scraping methods, following the order of nodes first and then large surfaces. If necessary, additional layers can be applied to the node areas, and the base material should preferably be made of synthetic non-woven fabric, not fiberglass.
3. Depending on different project needs, the film thickness should be 1.2-2mm, with 3-5 coats applied. The first coat can be slightly diluted with water to meet the thin coating requirements, allowing it to penetrate the base surface better and achieve better adhesion.
4. Color can be adjusted as needed to improve recognition and enhance aesthetic effects.
Scope of application:
JS-I type can be used for roofs. JS-I type can be used for indoor floors and interior/exterior walls, basements, water tanks, bathrooms, kitchens, balconies, etc.
Precautions:
1. Products should be stored sealed in a cool, dry place, with storage and transportation temperatures above 5°C.
2. The construction temperature should be between 5-35°C, and construction is strictly prohibited in windy, rainy days or under direct sunlight.
3. After the coating construction is completed, it should remain moist to avoid excessive drying and dehydration affecting the film formation.
4. Construction personnel must wear clean, lightweight shoes, and the soles must not be contaminated with sand, gravel, or other sharp objects to avoid dirtying or puncturing the coating.
Implementation standards:
JC/T894-2001
Meihui coating has passed the ISo9001 quality management system certification, ISO4001 environmental management system certification, China environmental labeling product certification, product quality are in line with the national standard, and even build a higher than the national standard Meihui standard.
Keyword:
Waterproof
MEIHUI
Online Inquiry
* Note: Please be sure to fill in the information accurately and keep communication open, we will get in touch with you as soon as possible
FUJIAN HUIXING COATINGS TECHNOLOGY DEVELOPMENT CO., LTD
TEL /400-995-8827
Address: Quanhui Petrochemical Park, Fujian Province
Website: www.fjhuixing.cn
Subscribe to us
Enter your email address to register for new service notifications.
Page Copyright © 2024 Fujian Huixing Coating Technology Development Co., Ltd.